Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Bras Enferm ; 72(3): 737-743, 2019 Jun 27.
Artigo em Inglês, Português | MEDLINE | ID: mdl-31269140

RESUMO

OBJECTIVE: to analyze occupational accidents with exposure of nursing technicians to biological material in a school hospital. METHOD: nursing technicians were invited to answer a questionnaire related to occupational accidents with biological material. RESULTS: 275 professionals from 9 hospital units participated. 76% reported having suffered an accident and the variables "age group" and "employment regime" showed a significant association for accidents (p<0.05). Those hired by the Consolidation of Labor Laws (CLT - Consolidação das Leis do Trabalho) employment regime were 3.5 times more likely to suffer accidents (p=0.04) and institutional capacity building did not show statistical significance (p>0.05). CONCLUSION: the increase in the number of training did not ensure the reduction of occupational accidents with biological material; and nursing technicians under the age of 30 were more vulnerable. Professionals with a CLT labor contract were more affected than the statutory employees.


Assuntos
Acidentes de Trabalho/estatística & dados numéricos , Assistentes de Enfermagem/estatística & dados numéricos , Exposição Ocupacional/efeitos adversos , Adulto , Idoso , Brasil , Distribuição de Qui-Quadrado , Estudos Transversais , Feminino , Hospitais/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/estatística & dados numéricos , Inquéritos e Questionários
2.
Rev Bras Cir Cardiovasc ; 28(4): 462-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24598950

RESUMO

INTRODUCTION: In vitro hydrodynamic characterization of prosthetic heart valves provides important information regarding their operation, especially if performed by noninvasive techniques of anemometry. Once velocity profiles for each valve are provided, it is possible to compare them in terms of hydrodynamic performance. In this first experimental study using laser doppler anemometry with mechanical valves, the simulations were performed at a steady flow workbench. OBJECTIVE: To compare unidimensional velocity profiles at the central plane of two bi-leaflet aortic prosthesis from St. Jude (AGN 21 - 751 and 21 AJ - 501 models) exposed to a steady flow regime, on four distinct sections, three downstream and one upstream. METHODS: To provide similar conditions for the flow through each prosthesis by a steady flow workbench (water, flow rate of 17L/min.) and, for the same sections and sweeps, to obtain the velocity profiles of each heart valve by unidimensional measurements. RESULTS: It was found that higher velocities correspond to the prosthesis with smaller inner diameter and instabilities of flow are larger as the section of interest is closer to the valve. Regions of recirculation, stagnation of flow, low pressure, and flow peak velocities were also found. CONCLUSIONS: Considering the hydrodynamic aspect and for every section measured, it could be concluded that the prosthesis model AGN 21 - 751 (RegentTM) is superior to the 21 AJ - 501 model (Master Series). Based on the results, future studies can choose to focus on specific regions of the these valves.


Assuntos
Velocidade do Fluxo Sanguíneo , Próteses Valvulares Cardíacas , Hidrodinâmica , Fluxometria por Laser-Doppler/métodos , Teste de Materiais , Ilustração Médica , Modelos Cardiovasculares , Pressão , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo
3.
ASAIO J ; 58(1): 40-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21266907

RESUMO

This study aims at the influence on hemolysis of the differences between the maximum and minimum amplitudes of pressure in the outlet of three roller pump models adjusted by dynamic calibration method. Tests were performed with silicone tubes (½ × (3)/(16) inches) in fluid analogous to blood and fresh bovine blood from slaughterhouse. Tests with analogous solution to blood were performed varying the dynamic calibration pressure between 78 and 500 mm Hg. Tests with fresh bovine blood were performed with the three pumps simultaneously, and pressure differences and free hemoglobin in the plasma were measured during 360 minutes. Tests with both analogous solution to blood and fresh bovine blood showed differences of mean pressures of pump 2 related to pumps 1 and 3 (p < 0.01). The different models of roller pumps analyzed presented differences in pressure amplitudes (p < 0.01) and hemolysis (p < 0.01) adjusted for the same dynamic calibration pressure. Raceway profile of pump 2 resulted in smaller pressure amplitude, implying lower hemolysis rate compared with pumps 1 and 3.


Assuntos
Ponte Cardiopulmonar/instrumentação , Ponte Cardiopulmonar/métodos , Hemólise , Animais , Calibragem , Bovinos , Desenho de Equipamento , Hemodinâmica/fisiologia , Hemoglobinas/análise , Pressão , Análise de Regressão , Temperatura , Fatores de Tempo
4.
ASAIO J ; 56(1): 12-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20051833

RESUMO

The rotation of rollers in cardiopulmonary bypass pumps propels the blood through various devices to reach the patient. Very occlusive settings may squeeze red blood cells, whereas a nonocclusive setting may result in retrograde flow. Occlusion of roller pumps may be regulated either by measuring the drop rate or by dynamic calibration. This study evaluated the influence of silicone tubing residual stress found on pump regulation. Silicone tubes obtained from two different suppliers were used in 6-inch DeBakey roller pumps. The variations occurring over time in the measurements of drop rate, dynamic calibration, and tube residual stress were analyzed. Covariance analysis of the four linear regressions has shown a progressive and accentuated reduction in drop rate (p < 0.002). It is noticeable that the angular coefficients of the drop rate measurements of the four silicone tubes are the same (p > 0.56). This reduction in drop rate measurements may affect the regulation of the pumps before surgical procedures. One probable cause for this reduction is the residual stress found in the silicone tubes. Settings based on the dynamic calibration process tended to be repeated over time. Simple linear regression test (angular coefficient equals zero) has shown a p > 0.79 showing no interference of the silicone tubes residual stress on dynamic calibration, suggesting that one should use this method to calibrate roller pumps.


Assuntos
Ponte Cardiopulmonar/instrumentação , Reologia/métodos , Estresse Mecânico , Calibragem , Reologia/instrumentação , Silicones
5.
Rev Bras Cir Cardiovasc ; 24(2): 188-93, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19768298

RESUMO

OBJECTIVE: Among the equipments used in cardiopulmonary bypass the roller pumps have great importance with various models available from several manufacturers. The calibration is an important factor in hemolysis rates and its potential is different in each. Researchers do not always approach details on the pump bed profiles assuming that the standardized calibration settings ensure equal and comparable values for all models of roller pumps. We have mainly two methods for calibration of pumps which also interferes on the hemolytic potential. In both of them, the characteristics of fluid impulsion defined by the pump bed design are not considered. The aim of this study is to compare the hydrodynamic profile of three models of roller pumps available in the Brazilian market. METHOD: The rollers occlusion was performed by measures of drop and dynamic calibration. Two different silicone diameter tubes were used (3/8 x 1/16 and 1/2 x 3/32 inches). RESULTS: The profiles showed differences in their variances, P<0.01 for drop rate measures and P<0.0001 for dynamic calibration. Different changes in pressure were found between the pumps analyzed (P<0.002). CONCLUSION: The measures of occlusion are dependent on the design of the pump bed and comparisons involving roller pumps should be performed with caution. Blood tests should be performed to verify the influence of changes in hemolysis pressure.


Assuntos
Ponte Cardiopulmonar/instrumentação , Fluxo Pulsátil/fisiologia , Análise de Variância , Brasil , Calibragem , Desenho de Equipamento , Modelos Lineares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...